DE Das medizinische Gerät laser-und des magnetischen Feldes der Therapie "VITJAS"        About quantum laser-lllt laser therapy = Quantum laser PRODUKTS = FAQ = Quantum laser BLOG = Contact Us

Kit VIP Kit 0 Kit 1 Kit 2 Kit 3
 

Complete set of nozzles universal for VITYAS Low Level Laser (LLLT) Quantum Therapy - 3 Nozzle

 

The registration certificate of Ministry of Health RB ¹ to them - 7.5832

The complete set of nozzles universal (further it is simple nozzles) represents a set of optical paths from polymer to the device of quantum therapy "Vityas". The complete set of nozzles allows to enter the directed radiation directly in bodies and to create optimum density of a stream of capacity on an output of a nozzle.

List Price: $122
 Sale Price: $48 + FREE SHIPPING

     

    The basic specifications:


     
    • Nozzles are made of the nontoxical optical organic glass well passing a light stream from 600 up to 890 nanometer (from red radiation up to a near infra-red spectrum).
    • Losses of energy of radiation at use of nozzles:
      • Losses on reflection from a face surface at input of infra-red radiation no more than 10 %;
      • Losses on absorption in a material of a nozzle, no more than 10 %;
      • Losses on dispersion from walls of an optical path no more than 15 %.
    • Weight of the complete set of nozzles in packing no more than 0,15 kg.
    • Overall dimensions of packing with nozzles - 190x150x45 mm.
    • Overall dimensions of nozzles and directions of optical radiations are resulted in figure 2.
    • The basic characteristics of the device of quantum therapy with nozzles are resulted in table 1.

Figure 2.

Table 1.

Scope

Nozzles

Gynecology, proctology Stomatology, otolaryngology, reflexotherapy Stomatology, otolaryngology
The name ¹1 ¹2 ¹3
Length nozzles (mm) 150 100 75
Diameter the bases (mm) 15±0,05 15±0,05 15±0,05
The connecting size of a radiator (mm) M24 M24 M24
Corner at top of a cone (hailstones) * 0 9 25
Factor of a transparency in a range from 600 nanometers up to 870 nanometers (%) * 70-75 55-60 70-75

           * - help sizes;

Security measures.

At carrying out of sessions of laser therapy with optical nozzles in the field of eyes it is necessary to dress to the patient goggles.

Goggles should not have cracks and having chopped off colour-filters, other defects worsening their protective properties.

Installation and change of optical nozzles should be made only at the switched off laser radiation of the device.

It is forbidden to direct the radiating ends of nozzles aside an eye, it is especial at an irradiation of the person.

 

  • The operating procedure with nozzles:


     

    1. To take the device for the handle and to turn an aperture of a radiator upwards.
    2. To take from packing an optical nozzle necessary for the given procedure and with the help of the cartridge to fix in a carvingaperture on the part of a radiator of the device. The cartridge is screwed on a groove before rigid fixing a nozzle. In order to prevent damage of a groove to not put significant efforts at screwing up. If the cartridge and a nozzle have not been disinfected, preliminary to disinfect them of 70 % spirit.
    3. At use of a nozzle ¹1 in gynecology or proctology to put on it(her) a condom and to fix it(him).
    4. To switch on a feed(meal) according to the passport on the device.
    5. Preparation for job and choice of an operating mode is carried out according to methodical recommendations and the passport on the device.
    6. At an irradiation of area of eyes to put on goggles and to the patient.
    7. To enter a nozzle into a cavity or to establish the radiating end on the necessary point or a zone of a body and to keep her(it) in this position during a session, for example, a hand of the patient.
    8. To press the button START-UP and to lead(carry out) a session of laser therapy. If necessary irradiations of the extended struck sites (a vagina, a direct gut, etc.) follows in pauses between radiations slowly and in regular intervals to move a nozzle more deeply for influence on the following site.
    9. Upon termination of the established duration of a session the device automatically will be switched off with submission of a sound signal.
    10. If necessary continuations of a session again to press the button START-UP and to repeat an irradiation before end of recommended influence.
    11. After deenergizing radiation to remove(take off) glasses.
    12. To switch off the device having disconnected from a network of a feed(meal).
    13. To remove(take off) a disposable condom.
    14. To unscrew, disinfect the cartridge and a nozzle of 70 % spirit and to lay in packing. On it the session of laser therapy comes to an end.

       

      Practical recommendations on use of nozzles.

       

      To disinfect the cartridge and nozzles follows rubbing of 70 % by spirit. To process solutions of formalin, alkalis, etc. active substances it is not recommended in order to prevent deterioration of optical characteristics of plexiglas and occurrence of cracks.

       

      Manufacturer's guarantees, service life and storages.

       

      The enterprise - manufacturer guarantees normal job of nozzles within 12 months from the date of sale at observance of conditions of transportation, storage and use, at absence of mechanical damages and thermal deformation.

      Warranty period of storage of 12 months from the date of manufacturing nozzles by the enterprise - manufacturer.

      At absence in a label of a mark about date of sale the warranty period of operation is established from the date of manufacturing nozzles by the enterprise - manufacturer.

      Storage of nozzles should be made in regular packing in a room at temperature from +5 up to +40 With and humidity up to 80 % at any atmospheric pressure.


 

 

Copyright (c)  low level laser therapy vityas.com